Remote Spectrum Monitors : MS27102A Installation : Wall Mounting Instructions
 
Wall Mounting Instructions
The MA27102A universal mounting bracket can accommodate mounting to a variety of wall structures. The user is responsible for selecting the appropriate wall fasteners for the structure of the wall, and the fasting system must be sufficient to carry the load of the instrument and cabling. Refer to Figure: MA27102A Vertical Pole Mounting during this procedure.
Note 
The illustration shows the instrument being installed vertically. The universal mounting bracket can be rotated 90 degrees and installed horizontally.
1. Install the universal bracket extensions as shown in Figure: MA27102A Vertical Pole Mounting (1).
2. Place the universal mounting bracket assembly against the wall at the desired location and mark the four mounting holes at the extension.
3. Install the universal mounting bracket assembly to the instrument as instructed in Installing the Mounting Bracket.
4. Attach the instrument and bracket assembly to the wall with the appropriate user-supplied wall fasteners (Figure: MA27102A Vertical Pole Mounting (2)). Use all four mounting holes on the universal bracket extensions. These slotted holes accept screws up to 6.3 mm (1/4 inch).
MA27102A Wall Mounting